The Jewell Instruments RailStar line offers high-performance sensors and control products for the rail transportation industry. Many of the products in this line meet CENELEC and AREMA Standards.
The Jewell DXI-100/200 Series single or dual digital inclinometer takes Jewell’s highly accurate analog closed-loop sensor technology to the next level. The DXI-100/200 is available with either RS-422 or RS-485 (Standard) digital interfaces. With a variety of options, including metric mounting threads, a flanged base, and CENELEC/AREMA certified, this product is easily customized to suit your specific application.


![]()
The Jewell Instruments RailStar line offers high-performance sensors and control products for the rail transportation industry. Many of the products in this line meet CENELEC and AREMA Standards.
| Dimensions | 1.63 × 3.63 × 1.85 in |
|---|---|
| Features | • Digital output |
| Applications | • Radar/Antenna Control |
| Market |
Static/Dynamic
| Input Range (°) | ±1.0 | ±3.0 | ±14.5 | ±30.0 | ±60.0 |
| Non Linearity (%FRO max2 | 0.06 | 0.025 | 0.02 | 0.02 | 0.03 |
| Scale Factor Tolerance (% maximum) | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 |
| Scale Factor Temperature Sensitivity (PPM/°C maximum) | 100 | 100 | 100 | 100 | 100 |
| Output at 0° Tilt (° max) | ±0.01 | ±0.01 | ±0.05 | ±0.05 | ±0.05 |
| 0° Output Temperature Sensitivity (°/°C, maximum) | 0.005 | 0.005 | 0.005 | 0.005 | 0.005 |
| Bandwidth (-3dB, Hz, nominal)3 | 3 | 6 | 30 | 30 | 30 |
| Transverse Axis Misalignment (° maximum) | 0.15 | 0.05 | 0.5 | 0.5 | 0.5 |
| Resolution & Threshold (µ) | 0.001 | 0.001 | 0.001 | 0.001 | 0.001 |
| Power on Repeatability (° maximum) | 0.001 | 0.001 | 0.001 | 0.001 | 0.001 |
| Repeatability (° maximum) | 0.001 | 0.001 | 0.002 | 0.002 | 0.003 |
Electrical
| Number of Axes | 1 or 2 |
| Supply Voltage Range (VDC) | 10 to 30 |
| Noise (g rms, maximum) | 0.005 |
| Input Current (mA, maximum) | 100 |
Environmental
| Operating Temperature Range | -40°C to +85°C |
| Storage Temperature Range | -40°C to +85°C |
| Vibration (grms) | 20 |
| Shock | 1500g, 1 msec, ½ sine |
Enclosure
| Housing Material | Anodized & Alodine Aluminum |
| Protection Class (per IEC 529) | IP67 |
| NEMA Enclosure Rating | 6 |
| Seal | MIL-STD-202, Method 112 |
| Connector Type | MS27476Y10D35P |
| Recommended Mating Connector | MS27473T10B35S |
Digital Output
| Interface | RS485 ½ duplex (default)/RS422 |
| Protocol | Proprietary (custom) |
| Baud Rate4 | 19200, 38400 (default), 57600, 115200, 230400 |
Notes:
2: Non-linearity is specified as the deviation of output referenced to a best fit straight line, independent of misalignment.
3: In default condition without averaging enabled
4: Default Baud Rate is 38400